Burner Doesn't Get Hot
Defective burner. Ohm test should read 20 to 30 ohms.
Defective burner receptacle. On plug-in type elements, pull out element and inspect receptacle and element plug ends. If excessive charring or pitting is noted, replace receptacle and element.
Defective infinite switch. Test for 240 volts AC at the two terminals going to the element when the switch is turned on.
Burner Only Goes to High
Defective infinite switch.